1. Room body
Room Dimension
Outside  size: L7000×W(4000+1255)×H3500(MM)
   Inside size: L6900×W3900×H2700(MM)
Optional:  rockwool wall pane, EPS top board.
Wall panelEPS sandwich wall 50MM thickness, colorful steel skin  board with thickness 0.376MM, White. Tongue & groove structure. Galvanized roof panel.
Basement     Galvanized  steel sheet and square steel pipe assembling, two rows of grill and three  rows of embossed plate. Basement height 330MM.
Driving ramp2pcs,  every pc 600MM width, made by embossed steel.                                                                                                 Optional  4pcs.
Personal door1-fold,  with view window, pressure lock, size: 680×2000(W×H).
Main door               3-fold,  inside steel type door, with window, size: 3000×2700(W×H).
2.  Ventilation system.
Intake fan          2sets 4KW professional  spray booth use centrifugal fan, capacity26000M³/H, air speed: 0.250.35M/S, air recycling times: 280  times/hour.
Exhaust fan                       1ses 4KW professional  spray booth use centrifugal fan.
HeatingInclude  10unit*3pcs*1000W shortwave infrared heating system, heating time 7000hours.Optional  gas burner.
3. Filtering system
Ceiling filter                          4sets,  holding net installation model. Ceiling filter can capture granules bigger  than 4μm. Its filtering rate reaches 98%. TSP1.4mg/m3.Optional: Add environment protect system.
Floor filter                  2sets,  installed horizontally.
Primary filter          1set,  plate structure filter. The Primary Filter Can Capture Granules Larger than  10μm.                                                                                  
4.Lighting  system
Ceiling light                8units×3pcs×28W, new type T5 tube. Room illumination1000LUX.
Ceiling light                8units×2pcs×28W, new type T5 tube. Installed vertically.
5.Control system
Electronic cabinet             Spray  & baking switch, light switch, emergency stop, breakdown alarm, timer,  temperature gauge, overload, hour meter, over heat protect, motor starts  directly.Optional:  Touch screen control box
Power                                 13.5KW.  (Either 220V, 380V, 400V or 415V is ok, do as customer needs.)


Model
B-200. Room inner size: 6.9M*3.9M*2.7M; Wall panel: EPS 50MM, color steel 0.376MM; Fan: 2pcs 4KW intake, 1PC 4KW exhaust; Ceiling lights and side lights; Heating:10units*3pcs*1000W tubes.
Motor power
(13.5+30)KW